Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
  Environmental and Engineering Geoscience   Email Content Delivery
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

Environmental and Engineering Geoscience; August 2006; v. 12; no. 3; p. 261-272; DOI: 10.2113/gseegeosci.12.3.261
© 2006 Association of Engineering Geologists
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Amidu, S. A.
Right arrow Articles by Olayinka, A. I.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Environmental Assessment of Sewage Disposal Systems Using 2D Electrical-Resistivity Imaging and Geochemical Analysis: A Case Study from Ibadan, Southwestern Nigeria

S. A. Amidu1 and A. I. Olayinka2

1 Department of Geology, Baylor University, One Bear Place #97354, Waco, TX 76798
2 Department of Geology, University of Ibadan, Ibadan, Nigeria

A case study is presented of integrated use of 2D electrical-resistivity imaging and geochemical analysis in environmental impact assessment of sewage disposal systems. This involved geoenvironmental studies around a septic tank in Ibadan, southwestern Nigeria. The area is underlain by quartzites and quartz schists, whereas the weathered profile consists of sandy and silty clay with some gravel. Twenty-two multi-electrode resistivity profiling lines were taken using the Wenner array. The electrode spacing ranged from 1 to 8 m with a station interval of 1 m. Resistivity data analysis involved inversion using a rapid least-square technique and construction of iso-apparent resistivity contour maps. Four pits were dug, with two of the pits located on points of resistivity lows and the other two pits on points of high resistivity values. The pits were dug to a total depth of 2 m and soil samples collected from each pit at 0.5-, 1.0-, 1.5-, and 2.0-m depths. The samples were analyzed for conductivity and for Pb, Fe, Cu, Cr, and nitrate concentrations. The resistivity survey yielded low resistivity values at locations close to the septic tank and higher values farther from it. This agreed with the electrical conductivities measured for soil samples. Statistical analyses of the conductivity variation with distance from the septic tank yielded a negative correlation coefficient of between –0.92 and –0.52, indicating an inverse relationship between the two quantities. Similar relationships were established for analyzed chemical constituents. The environment is impacted by the septic system as shown by soil sampling and geophysical results. The results demonstrate that pollution mapping in a basement complex environment can be carried out using the approach described in this paper.

Key Words: Environmental Assessment • 2D Electrical-Resistivity Imaging • Geochemical Analysis • Septic Tank • Nigeria




This article has been cited by other articles:


Home page
Vadose Zone JHome page
S. A. Amidu and J. A. Dunbar
Geoelectric Studies of Seasonal Wetting and Drying of a Texas Vertisol
Vadose Zone J., August 1, 2007; 6(3): 511 - 523.
[Abstract] [Full Text] [PDF]